Immersion heater on triangular flange - 21 kW - 400 V 3P - Specific load 8 W/cm2

Product N° : 1789.59
Vulcanic Vulcaloy immersion heater on triangular flange View1
search
  • Vulcanic Vulcaloy immersion heater on triangular flange View1
  • Vulcaloy immersion heater on triangular flange Vulcanic DrawA1000NC120

The VULCALOY® electric immersion heater on triangular flange is designed for heating tap water in static mode (tank, hot water tank) or in circulation in a heater, up to a maximum of 100 °C and under a maximum operating pressure of 9.5 bar g.

It consists of 3 shielded heating elements made of Incoloy® 825, loaded at 8 W/cm2, welded to a stainless steel triangular flange. The immersion heater is equipped with an IP55 polyamide connector terminal box.

Can be made , Under 29 days

Immersion heater power (W) :
21000
Power tolerance :
+5/-10%
Supply voltage :
400 V 3P
Minimum permissible temperature (°C) :
5
Maximum permissible temperature (°C) :
110
Maximum permissible pressure / maximum PS (bar.g) :
10
Specific load (W/cm2) :
8
Heater length A (mm) :
1000
Non heating length Nc (mm) :
120
Diameter of heating pins (mm) :
16
Material of the heating pins :
825 Incoloy®
Flange material :
304L Stainless steel
Method of connection of the pins to the flange :
Welded
Pin terminals :
M5 steel threaded terminals
Connector terminal box :
V1 Terminal box - IP55 - Polyamide
Cable gland diameter :
ISO 25
Cable gland tightening capacity :
Cable Ø 9 to Ø 18 mm
Cable gland material :
Polyamide
Weight (kg) :
3.6
Accessories included :
Ethylene propylene flange seal
  • User manual