Recycled or wasted water circulation heater - 2 Non-insulated DN80 bodies - 36 kW - 400 V 3P

Product N° : 10702.31
Vulcanic DN80 double vessel non-insulated liquid circulation heater Vulcanic View1
search
  • Vulcanic DN80 double vessel non-insulated liquid circulation heater Vulcanic View1
  • ND80 double vessel non-insulated liquid circulation heater Vulcanic DrawLN900B0

Liquid circulation heater for heating recycled or wasted water to a maximum temperature of 100 °C and a maximum operating pressure of 14.2 bar.g. Consisting of 2 DN80 316L non-insulated stainless steel bodies with 2" gas tapped inlet/outlet connections.

The heater is equipped with a body safety thermostat with automatic reset, fixed temperature of 115 °C and 2 screw-in immersion heaters M77 x 200 with a unitary power of 18 kW/400 V 3P.

Last items in stock 2 items

Total heater power (kW) :
36
Power tolerance :
+5/-10%
Heater supply voltage :
400 V 3P
State of the fluid to be heated :
Liquid
Type of fluid to be heated :
Recycled or waste water
Number of heating units :
2
Heater insulation :
Not insulated
Specific load (W/cm2)
8
Minimum operating temperature (°C) :
5
Maximum operating temperature (°C) :
100
Maximum operating pressure (bar.g) :
14.2
Minimum flow at rated power :
2 m3/h
Body diameter DN :
80
LN pole of the heater (mm) :
900
Body material :
316L Stainless steel
Internal body treatment :
Sans
External body treatment :
Sans
Input/output tapping :
2'' gas tap
Support stands material :
Protected steel
Insulation material :
Sans
Body safety device :
Fixed 115°C thermostat with automatic reset
Immersion heater part number :
2077.84
Unit power of the immersion heater (kW) :
18
Material of the heating pins :
825 Incoloy®
Joining of pins to the cap :
Brazed
Cap thread diameter :
M77 x 200
Cap thread material :
Brass
Connector protection box :
H1 Terminal box - IP55 - Polyamide
Cable gland :
1 ISO 25 polyamide cable gland Ø 9 to 18 mm
Category of the PED 2014/68/EU :
Equipment covered by article 4§3
Min. permissible temperature / TS min. (°C) :
5
Max. permissible temperature / TS max. (°C) :
110
Max. permissible pressure / PS max. (bar.g) :
15
Heater mounting position :
Horizontal
Construction code :
Standard Vulcanic