Liquid circulation heater for heating water-based liquids to a maximum of 100°C and a maximum operating pressure of 14.2 bar.g. Consisting of 2 DN50 non-insulated steel bodies with 1''1/2 gas tapped inlet/outlet connections.
The heater is equipped with a body safety thermostat with automatic reset, fixed temperature of 115 °C and 2 screw-in immersion heater M45 x 200 with a unitary power of 6 kW/400 V 3P.