Recycled or wasted water circulation heater - 1 insulated DN50 body - 9 kW - 400 V 3P

Product N° : 10641.13
Vulcanic DN50 single vessel insulated liquid circulation heater View1
search
  • Vulcanic DN50 single vessel insulated liquid circulation heater View1
  • ND50 single vessel insulated liquid circulation heater Vulcanic DrawLN900B0

Liquid circulation heater for heating recycled or wasted water to a maximum temperature of 100 °C and a maximum operating pressure of 14.2 bar.g. Consisting of 1 DN50 insulated steel body with 1''1/2 gas tapped inlet/outlet connections.

The heater is equipped with a body safety thermostat with automatic reset, fixed temperature of 115 °C and a screw-in immersion heater M45 x 200 with a unitary power of 9 kW/400 V 3P.

Can be made , Under 28 days

Total heater power (kW) :
9
Power tolerance :
+5/-10%
Heater supply voltage :
400 V 3P
State of the fluid to be heated :
Liquid
Type of fluid to be heated :
Recycled or waste water
Number of heating units :
1
Heater insulation :
Insulated
Specific load (W/cm2)
8
Minimum operating temperature (°C) :
5
Maximum operating temperature (°C) :
100
Maximum operating pressure (bar.g) :
14.2
Minimum flow at rated power :
1 m3/h
Body diameter DN :
50
LN pole of the heater (mm) :
900
Body material :
Acier
Internal body treatment :
Sans
External body treatment :
High temperature aluminium paint
Input/output tapping :
1''1/2 gas tap
Support stands material :
Protected steel
Insulation material :
Rockwool in a protected steel jacket
Body safety device :
Fixed 115°C thermostat with automatic reset
Immersion heater part number :
2145.32
Unit power of the immersion heater (kW) :
9
Material of the heating pins :
904L Stainless steel
Joining of pins to the cap :
Brazed
Cap thread diameter :
M45 x 200
Cap thread material :
Brass
Connector protection box :
H1 Terminal box - IP55 - Polyamide
Cable gland :
1 ISO 25 polyamide cable gland Ø 9 to 18 mm
Category of the PED 2014/68/EU :
Equipment covered by article 4§3
Min. permissible temperature / TS min. (°C) :
5
Max. permissible temperature / TS max. (°C) :
110
Max. permissible pressure / PS max. (bar.g) :
15
Heater mounting position :
Horizontal
Construction code :
Standard Vulcanic
  • User manual

  • Datasheet