Vulcatherm Hot - Water 110 °C max - Heating power 6kW / 400V 3P - ?Pressurized circuit with mechanical expansion

Product N° : 10815.06
Temperature control units Vulcatherm Hot Water 10815 Vulcanic Vue1
search
  • Temperature control units Vulcatherm Hot Water 10815 Vulcanic Vue1
  • Temperature control units Vulcatherm Hot Water 10815 Vulcanic Draw
  • Opertaing curve of Vulcatherm Hot Vulcanic Draw

Vulcatherm temperature control unit for heating and regulating a closed water loop from 10°C to 110°C max intended for applications of autoclaves, sterilisers, mixers, melters, etc. Heating power 6 kW / 400 V 3P + E. Pressurization of the circuit at 1 bar.g with mechanical expansion by membrane expansion tank. max admissible pressure of 10 bar.g in the circuit.

Can be made , Under 42 days

The Vulcatherm temperature control unit consists of:

- 1 Electrical heater with temperature sensors

- 1 Pump

- 1 Membrane expansion tank

- 1 Safety valve

- 1 Electrical cabinet with integrated Central Management System

- Sensors for control and safety

in a painted frame equipped with castors

Vulcatherm model :
Hot
Heat transfer medium :
Water
Type of heat transfer medium expansion :
Pressurisation to 1 bar.g with mechanical expansion (Via expansion tank)
Heating power (kW) :
6
Tolerance on heating power :
+5/-10%
Supply voltage :
400 V 3P + E
Maximum current absorbed at 400 V 3P (A) :
12
Maximum temperature of the heat transfer medium (°C) :
110
Minimum temperature of the heat transfer medium (°C) :
10
Maximum pressure allowed in the current (bar.g) :
10
Nominal flow of the heat transfer medium :
0.9 m3/h at delta P of 3.5 bar
Expansion volume (l) :
2
Medium inlet and outlet connections :
3/4'' male gas thread
Système de gestion centralisé (automate)
Integrated central management (controller)
Body material :
Painted frame equipped with castor
Vulcatherm dimensions (mm) :
L: 340 x H: 670 x D: 570
Weight (kg) :
70
  • User manual