Vulcatherm Hot/Cold - Water 140 °C max - Heating power 6kW / 400V 3P - ?Pressurized circuit with electrical expansion
Vulcatherm temperature control unit Hot/Cold for heating, cooling and regulating a closed water loop from 10°C to 140°C max intended for molding, thermoforming applications, etc. Heating power 6 kW / 400 V 3P + E. Cooling by water/water exchanger supplied by the customer's industrial water network. Pressurization of the circuit at 3 bar.g with electric expansion by solenoid valve. max admissible pressure of 14 bar.g in the circuit.
The Vulcatherm temperature control unit consists of:
- 1 Electrical heater with temperature sensors
- 2 Pumps
- 1 Membrane expansion tank
- 1 Filling and expansion tank
- 1 Water/Water Exchanger
- 1 Electrical cabinet with integrated Central Management System
- Sensors for control and safety
in a painted frame equipped with castors
- Vulcatherm model :
- Hot/Cold
- Heat transfer medium :
- Water
- Type of heat transfer medium expansion :
- Autonomous pressurisation to 3 bar.g with electric expansion (via solenoid)
- Heating power (kW) :
- 6
- Tolerance on heating power :
- +5/-10%
- Supply voltage :
- 400 V 3P + E
- Maximum current absorbed at 400 V 3P (A) :
- 12
- Maximum temperature of the heat transfer medium (°C) :
- 140
- Cooling power :
- 20kWFluide130Eau20
- Minimum temperature of the heat transfer medium (°C) :
- 10
- Cooling device :
- Water/Water exchanger with cooling by industrial water from the customer's network
- Maximum pressure allowed in the current (bar.g) :
- 14
- Nominal flow of the heat transfer medium :
- 0.9 m3/h at delta P of 4.3 bar
- Expansion volume (l) :
- 14.3
- Medium inlet and outlet connections :
- 3/4'' female gas thread
- Connections for cooling:
- 1/2'' female gas thread
- Système de gestion centralisé (automate)
- Integrated central management (controller)
- Body material :
- Painted frame equipped with castor
- Vulcatherm dimensions (mm) :
- L: 400 x H: 780 x D: 860
- Weight (kg) :
- 60